Your water heater wont work properly if the igniter wont spark. Aside from lighting the gas burner, the pilot also heats the thermocouple, which creates a small amount of electricity to hold the electromagnetic valve open inside of the gas control valve. An induced draft water heater is a type of water heater that uses a small fan, to draw the combustion gas from the combustion chamber. Slightly tighten the drain valve using the pipe wrench. Extracted igniter wires that come out of the white connector are the first I blame most. Does the Honeywell thermostat have a reset button? Honeywell Water Heater Sensor Failure [5 Easy Fixes], Why Duraflame Heater Flame Not Working [Reasons + Solutions], Richmond Tankless Water Heater Troubleshooting [A Complete Guide], Richmond Electric Water Heater Troubleshooting [A Complete Guide], Richmond Gas Water Heater Troubleshooting [A Complete Guide], Richmond Water Heater Blinking Light Codes [Why+ How To Fix], Richmond Water Heater Gas Valve Problems [Why + How To Fix], > LED is not lit, or the thermopile didnt get the normal temperature yet. Have patience when working on these things, and make sure that you are taking the correct safety precautions. The most common. Or, the defective spark electrode itself. Also, check that the thermostat is set to the proper temperature. How do I know if my water heater is working? Whether it be identifying the problem or replacing a part, let's take a look at what you should do when your water heater igniter won't spark. To determine if the igniter is defective, first make sure the igniter is getting voltage. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Replace the defective pipe. Anyway, note down some possible reasons behind the interruption in the fuel supply: Follow the below few phases to fix the gas supply issue: As for the first step, check to see if there is air in the gas line. Another possibility is that there is something blocking the igniters contact with the wire coil in the furnace. Your Honeywell water heater igniter is not working due to loose igniter wiring, dirty thermopile, and bad igniter. 01 - Water Heater Igniter. Anyway, from this article, you are getting the complete solutions guide related to the status light no blinking issue. Set the thermostat or the device's controller slightly above the current room temperature. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. But you might be struggling to figure out what kind of paint to use on garage walls. Finally, you have to reset the tripped thermal switch to get back the element function again. Clogged base-ring filters or the flame arrestor. Now look for loose wiring to the switch, which is leading the switch to trip unexpectedly. Then, set the gas control knob to the Off position to turn off the unit. 7 Flashes = Gas Control Valve Failure. It will ensure a fluent gas flow. Thenswitch the dial to very hot for 10 seconds. The most common symptoms of a broken water heater are the smell of gas. All Right Reserved by FIREPLACEHUBS. Repair the valve issue with the help of a plumber. Inspect the water heater for any visible cracks or leaks present. If youre having trouble getting your water heater to light its pilot light, first check the following spark electrode for dirt and corrosion since this could be your problem. The most common Honeywell water heater problems are the heater not heating or the heater keeps shutting off. The other leading reason for the low heating problems include: The Honeywell water heater is making noise because the fan has to turn on quickly to create a flow of air through the heater. COPYRIGHT 2023. FV sensors also go into lockout mode when the sensor becomes damaged or defective. If your Honeywell water heaters thermostat is bad, your heater will produce no hot water or enough hot water. When the piezo igniter is pressed down and released, an electric spark is produced to light the primary gas burner in the water heater. how to fix Honeywell hot water heater status light blinking 7 times, solution guide in the hot water heater pilot wont light section of the article, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Press the button firmly. The control board will throw a code if there is a problem with the voltage. You will know it is working if you feel the heat coming from the unit. Then, check and replace the bad gas control valve. You may have to dim the room lights to see the spark. Continuously thermopile generates electric power while the gas valve/temperature knob is turned off. How do I know if the gas valve is bad on my water heater? A defective thermostat can be changed by professionals to overcome this problem. Bad thermopile or defective igniter are the two main culprits that cause the status light to not blink. If that is not the problem, you may have a bad thermocouple on your hands. Here you go: First up, turn off the power to your water heater. If I understand correctly, your pilot flame is lighting correctly. Press and hold down on the gas control knob, or pilot set button. When the pilot light is on, turn the gas control knob to the desired temperature settings. How long does the igniter last on water heater? Insufficient air supply may be the culprit due to a clogged air screen. That includes: The below guidelines will help to fix the tripped switch issue. Alternatively, if the pilot light goes out right after you light it, you want to reset the door switch, or high-limit reset switch. The electronic igniter, will either light the pilot light or will light the gas directly. Upvote Due to a loose connection of the connector, the red status light will not blink. How do I reset my Honeywell water heater? In the following table we will explain what different times LED flashes mean, their causes, and solutions: Turn on your heaters Pilot, and for 10 seconds, switch the Pilot dial to Very Hot. Then for 10 seconds, switch the dial to Hot. And again, for 10 seconds, change it to Pilot.. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. This makes the pilot flame small and unsustainable. Honeywell Water Heater Is Not Hot Enough, 3. 2 Flashs = Thermopile low voltage. I hold the pilot button in, click on the button but the status light indicator will not come on at all and theres no indication the pilot inside the tank is on. Or reset your water heater. This switch can be found by viewing the door at the base of the tank. Tighten all the wiring connections. Burner Will Not Ignite 8. 4 Flashes = Temperature Exceeded. As I mentioned earlier, three culprits: loose igniter wiring, dirty thermopile, and bad igniter cause the igniter to not work. If you see below 400 millivolts, be sure it is defective. First up, check the thermostat for an accurate reading. Check the T&P valve and verify whether it is in good working condition or not. Hopefully, if your heater goes through any of the above trouble, you will fix it yourself. for the Honeywell water heater? Below, I will break down everything you need to know to let the igniter function again. It may also be caused due to a failing pressure switch. Due to the high temperature, the T&P starts leaking. Once the pilot light is on, continue pressing down on the pilot switch for a minute to allow the flame to heat up the thermocouple. Inspect the base-ring filter and the flame arrestor to look for any dirt and debris. Eric,your tutorial was very helpful, Im from El Paso as well. After resolving the pilot issue and there is still no blinking on the status light, a bad igniter or malfunctions from the igniter is the second suspect. If no spark is coming, check the igniter connection for any corrosion. Also, it should not touch the metal pilot tube and manifold tube. If this doesnt work, then it might mean that the spark electrode is defective so you will have to replace it before being able to light your pilot light again. If the pilot light wont light and there is no spark, the problem usually lies with the spark electrode. The pilot light in your water heater is a small device that is designed to provide the flame to light the gas released out of the gas valve and main burner. Plus, your Honeywell water heater beeping, keeps shutting off, heater overheating and ignition failure may bother you frequently. If so, simply straighten the kinked tube. Now, check the spark wire and ensure it is grounded properly. Get free, zero-commitment quotes from pro contractors near you. The blinking light on a different number of times indicates that theres something up with your water heater and needs to be fixed as soon as possible. Switch the knob back to the Pilot position. Continue with Recommended Cookies. Check to make sure the thermocouple connection to the control valve is tight. Insufficient fuel supply> Open the gas shut-off valve all the way.> Ensure proper gas pressure on the heater. Hold the gas control knob in while clicking the igniter button and looking through the viewport (inside the water heater to the left). This means, if the power is out, you will not be able to light the hot water heater. > Clean out base-ring filters & the flame arrestor with the brush-attached vacuum cleaner. After doing all the above, reassemble the heater and relight the pilot. The reasons behind this difficulty are: Before your too-hot Honeywell water heater creates any major hitch, you need to fix it immediately. Check and replace the defective heating system, damaged or broken dip tube, leaky faucets, malfunctioning pilot lights, and faulty thermostat. | How To Stop Wind From Blowing Out Pilot Light | Honeywell Water Heater Pilot Light Wont Light? 1 Additionally, these devices are fueled with flammable natural gas. You will see two black connectorson the gas control valve. Remove the front access panel of your water heater. If the control board is faulty, it might also need to be replaced. If the issue is related to only the pilot and igniter, simply cleaning and replacing the defective parts can resolve the problem. A damaged thermocouple could be the next problem on the list. To do this, turn the water temperature dial to Low and the On/Off/Pilot knob to Pilot. If your Honeywell water heater has no status light, our guide will prove quite effective in resolving this problem. So, keep reading between the lines. However, the more advanced problems will most likely need a licensed plumber. If you move through this list, and still cannot find the problem, then you know it is time to call in a professional. Then, ensure that the reset button of the thermostat is working correctly. Step 8. Now, use an adjustable wrench to unscrew the pilot tube and the gas supply tube from the control valve. Then, you will need to set your multimeter to read millivolts. Then solve this problem by following the quick solutions below: Your heater will not turn on and stop working when your Honeywell water heater error code flashes. Honeywell Hot Water Heater No Status Light [7 Easy Solutions] 1. So, whenever you start to struggle with any issue with your heater, just follow our Honeywell water heater troubleshooting guide and fix it by yourself.